Tenants now ask a question that building managers rarely heard five years ago: how is the air in here? Indoor air quality has moved from a comfort issue to a leasing, health and productivity topic, and sensors make it possible to answer with numbers. This article is a how-to for choosing, placing and acting on air quality sensors. It sits in Smart Buildings and extends our earlier overview of indoor air quality IoT in Illinois office buildings with a focus on implementation.

What You Can Measure

MeasureWhat It Tells YouCommon Use
Carbon dioxide (CO2)How well a space is ventilated relative to occupancyAdjust outside air, spot overcrowded rooms
Fine particles (PM2.5)Smoke, dust and combustion particlesWildfire smoke response, filter checks
Temperature and humidityComfort and mold riskControl and complaint analysis
Volatile organic compounds (VOCs)Off-gassing from materials and cleaning productsSpot sources after renovations
Carbon monoxide and nitrogen dioxideCombustion sources, garagesSafety near parking and mechanical rooms
Differential pressureAirflow direction between roomsLabs, clinics and filter loading

CO2 is the most useful single indicator in office buildings because it reflects how much fresh air each person is getting. It is not a direct measure of germs or pollution, so treat it as a ventilation signal, not a verdict on health.

Choosing Sensors

  • Accuracy and calibration: Low-cost sensors drift. Ask how often calibration is needed and whether the sensor self-corrects. For CO2, look for dual-channel or auto-calibration designs and plan periodic checks against a reference.
  • Particle sensing: Optical sensors are good for trends and alerts but less precise than lab instruments.
  • Connectivity: Wireless sensors suit retrofits. Check battery life and signal strength in your building.
  • Data access: Choose sensors that send data to your platform through open interfaces, not locked apps.
  • Security: Treat them like any networked device, with secure setup and updates.

Where to Put Them

Place sensors where people breathe, not near vents, doors or windows where readings spike. Typical heights are in the breathing zone, around desk level or a little higher. Representative locations include open office areas, conference rooms, classrooms, lobbies and air handler return paths. A rule of thumb is one sensor per zone served by a single air handler or terminal, with extra units in high-occupancy rooms. Add outdoor sensors for comparison, so you can tell whether a rise in particles comes from inside or from smoke drifting in.

Turning Readings Into Action

Data matters only if it changes something. Define response rules before the sensors go live.

  1. Set target ranges for each measure and each space type.
  2. Link to ventilation control. Demand-controlled ventilation raises outside air when CO2 climbs and reduces it when rooms are empty, saving energy while protecting air quality.
  3. Trigger maintenance. Rising filter pressure drop, or persistent high particle levels after filtration, calls for a filter or equipment check.
  4. Create smoke and event modes. When outdoor air is poor, such as during wildfire smoke episodes, the system can limit outside air intake and run higher filtration.
  5. Report to tenants. Share simple summaries, such as percent of occupied hours within target.

The Standards Context

ASHRAE Standard 241, published in July 2023, addresses control of infectious aerosols and sets targets for equivalent clean airflow per occupant, with provisions for periods of elevated risk and a building readiness plan. It is a design and operations standard, not a requirement to install sensors, but sensor data helps show that ventilation and filtration deliver what was intended. Building owners should confirm what applies to their projects, since adoption depends on local authorities.

Energy and Air Quality Together

More fresh air costs energy, especially in Illinois winters and humid summers. The goal is to deliver the right amount to each space at the right time. Sensor-based control often lets buildings avoid overventilating empty rooms while ensuring crowded rooms get enough. For the energy side, see real-time energy monitoring for facility managers, and for equipment data see IoT HVAC monitoring in large buildings.

A Training Room Scenario

Consider a Champaign-area building owner with an older office floor and a leased training room. Occupants complain of stuffiness in the afternoon. The owner installs CO2, temperature and particle sensors in the training room, two open areas and the air handler return, plus one outdoor unit. Data shows CO2 climbing above target during classes because ventilation follows a fixed schedule. After enabling demand-controlled ventilation, CO2 stays within range during classes and falls back when the room empties, without raising overall energy use. The owner shares a monthly summary with tenants. For comparison, school settings are covered in connected campus safety in Illinois schools, and local providers appear on the Champaign Smart Buildings page.

Common Challenges

Sensor Drift

Uncalibrated sensors mislead. Schedule checks and replace units that fail them.

Too Much Data, No Decision

Pick a few measures and a clear response plan first.

Privacy and Perception

Air sensors do not track people, but occupancy-linked data can raise questions. Explain what is collected and use aggregate data.

Health Claims

Avoid promising health outcomes. Report measured conditions and describe actions taken.

What's Coming Next

Expect lower-cost sensors with better accuracy, more tenant-facing dashboards, tighter links between air quality and energy optimization and growing interest in air quality as a lease and certification topic. Expect smoke season responses to become standard building procedures.

Explore More

Browse more Smart Buildings coverage, and see how smart buildings in Chicago use these systems.

Frequently Asked Questions

What should an office measure first for indoor air quality?

CO2 and temperature, since they show how well each space is ventilated and how comfortable it is. Add particles and humidity next, then other measures as needed.

Does a high CO2 reading mean the air is unhealthy?

Not directly. CO2 is a sign of ventilation relative to occupancy. High levels suggest the room needs more fresh air, but it does not measure germs or other pollutants.

How many sensors does a floor need?

A common approach is one per air handling zone, with additional sensors in crowded rooms such as conference spaces, plus one outdoors for comparison.

Can air quality sensors reduce energy use?

Yes, when linked to demand-controlled ventilation. The system supplies more outside air only when rooms are occupied and CO2 rises.

How often do sensors need calibration?

It depends on the model. Some self-calibrate, while others need periodic checks. Ask the supplier and plan routine verification against a reference.

What is ASHRAE Standard 241?

It is a standard published in 2023 that sets targets for equivalent clean airflow per occupant and provides practices for reducing infectious aerosols, including provisions for periods of elevated risk.

Frequently asked questions

CO2 and temperature, since they show how well each space is ventilated and how comfortable it is. Add particles and humidity next, then other measures as needed.

Not directly. CO2 is a sign of ventilation relative to occupancy. High levels suggest the room needs more fresh air, but it does not measure germs or other pollutants.

A common approach is one per air handling zone, with additional sensors in crowded rooms such as conference spaces, plus one outdoors for comparison.

Yes, when linked to demand-controlled ventilation. The system supplies more outside air only when rooms are occupied and CO2 rises.

It depends on the model. Some self-calibrate, while others need periodic checks. Ask the supplier and plan routine verification against a reference.

It is a standard published in 2023 that sets targets for equivalent clean airflow per occupant and provides practices for reducing infectious aerosols, including provisions for periods of elevated risk.

Related articles